<style><!-- [et_pb_line_break_holder] -->html.et_fb_desktop_mode #main-header, html.et_fb_preview_active #main-header, html.et_fb_desktop_mode #top-header, html.et_fb_preview_active #top-header, html.et_fb_desktop_mode #main-footer, html.et_fb_preview_active #main-footer {<!-- [et_pb_line_break_holder] --> display: none!important;<!-- [et_pb_line_break_holder] -->}<!-- [et_pb_line_break_holder] --></style>

Roofing Specialists in

The Wellington Region

Contact Us

022 395 5676

TRS5

TRS 5 profile is designed  for residential and industrial roofing and cladding. G550 grade steel with minimum 0.40mm BMT and maximum 0.55BMT gives more resilience to damage.

General

Minimum Roof Pitch

Effective Cover

Max. Unsupported Overhang

3 Degree

765 mm

Contact “The Roofing Store”

ROOF FIXINGS

LOW/MEDIUM WIND ZONE

Timber: class 4 12 x 65mm with neo washer and embossed washer

Steeltite: 12 x 55mm with neo washer and embossed washer

HIGH WIND ZONE

Timber: class 4 12 x 65mm with neo washer and embossed washer, approved profile washers with EPDM

Steeltite: 12 x 55mm with neo washer and embossed washer, approved profile washers with EPDM

WALL CLADDING FIXINGS

Cladding fixing on 20mm

Timber Battens (please ensure compatibility as sometreatments may cause a reaction )

Every pan with 12 gauge class

4 screws with neo washers

TRS6

Trim 6 is the classic, bold rib profile used commercially and at home on your house roof. High performing, attractive for both roofing and cladding. G550 grade steel with minimum 0.40mm BMT and maximum 0.55 BMT gives more resilience to damage.

SPECIFICATION AT A GLANCE

GENERAL

Minimum Roof Pitch

Effective Cover

Max. Unsupported Overhang

4 Degree

762 mm

Contact “The Roofing Store”

GENERAL

End Span 0.40/0.55 BMT

Internal Span 0.40/0.55 BMT

1100 mm/1300 mm

1450 mm/2000 mm

TRS Corrugate

TRS Corrugate for roofing and cladding offers the timeless elegance and matchless adaptability of the traditional corrugated profile. G550 grade steel with minimum 0.40mm BMT and maximum 0.55 BMT gives more resilience to damage.

SPECIFICATION AT A GLANCE

GENERAL

Minimum Roof Pitch

Effective Cover

Max. Unsupported Overhang

8 Degree

762 mm

Contact “The Roofing Store”

GENERAL

End Span 0.40/0.55 BMT

Internal Span 0.40/0.55 BMT

700 mm/900 mm

900 mm/1300 mm